Device type · DSP
System, Balloon, Intra-Aortic And Control
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
DSP
Cardiovascular
Device class
Class II
FDA decisions since 2015
12
510(k), De Novo and PMA
Adverse event reports
9,312
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- System, Balloon, Intra-Aortic And Control
- Product code
- DSP
- Device class
- Class II
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.3535
- Specialty
- Cardiology, Interventional Cardiology
- FDA record
- Classification database entry for DSP
Latest FDA decisions
The 8 newest of 12 since 2015.
K250542 · Decided Mar 26, 2025 · 30 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
- AC3 Series IABP510(k)
K232343 · Decided Aug 30, 2023 · 26 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
K201112 · Decided May 27, 2020 · 30 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
K200634 · Decided Apr 9, 2020 · 30 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
K192238 · Decided Nov 12, 2019 · 85 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
- UltraFlex IAB510(k)
K190101 · Decided Jun 28, 2019 · 157 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
- Fiberoptix IAB510(k)
K190117 · Decided Jun 13, 2019 · 140 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
K181122 · Decided May 31, 2018 · 31 days after receipt
Device type: System, Balloon, Intra-Aortic And Control (DSP) · Cardiology
Reports received
9,312
Received Nov 1, 2025 to Nov 19, 2026. Includes 29 of another or unstated type.
Malfunction reports
9,143
98% of reports
Injury reports
97
1.0% of reports
Death reports
43
0.5% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 535 | 8 | 1 | 0 |
| Jan 24 | 530 | 7 | 0 | 0 |
| Feb 24 | 623 | 5 | 1 | 0 |
| Mar 24 | 571 | 10 | 3 | 0 |
| Apr 24 | 611 | 4 | 1 | 2 |
| May 24 | 631 | 7 | 7 | 0 |
| Jun 24 | 526 | 8 | 0 | 0 |
| Jul 24 | 599 | 17 | 4 | 0 |
| Aug 24 | 621 | 13 | 6 | 0 |
| Sep 24 | 596 | 10 | 4 | 0 |
| Oct 24 | 663 | 19 | 1 | 1 |
| Nov 24 | 532 | 17 | 3 | 0 |
| Dec 24 | 647 | 12 | 7 | 0 |
| Jan 25 | 606 | 6 | 1 | 0 |
| Feb 25 | 550 | 7 | 4 | 0 |
| Mar 25 | 732 | 14 | 7 | 0 |
| Apr 25 | 668 | 7 | 3 | 0 |
| May 25 | 492 | 5 | 2 | 0 |
| Jun 25 | 516 | 6 | 3 | 0 |
| Jul 25 | 709 | 7 | 5 | 0 |
| Aug 25 | 497 | 8 | 2 | 0 |
| Sep 25 | 602 | 9 | 1 | 0 |
| Oct 25 | 626 | 9 | 5 | 0 |
| Nov 25 | 598 | 11 | 1 | 0 |
| Dec 25 | 783 | 2 | 0 | 0 |
| Jan 26 | 1,733 | 7 | 11 | 0 |
| Feb 26 | 615 | 6 | 5 | 0 |
| Mar 26 | 681 | 8 | 1 | 0 |
| Apr 26 | 809 | 8 | 3 | 0 |
| May 26 | 602 | 6 | 0 | 0 |
| Jun 26 | 597 | 4 | 2 | 4 |
| Jul 26 | 721 | 13 | 11 | 3 |
| Aug 26 | 708 | 15 | 1 | 9 |
| Sep 26 | 631 | 12 | 2 | 3 |
| Oct 26 | 665 | 5 | 6 | 10 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Gas/Air Leak2,019
- Inability to Auto-Fill739
- Leak/Splash691
- Appropriate Device Problem Term/Code Not Available668
- Inflation Problem446
- Device Sensing Problem413
- Obstruction of Flow374
- Pacing Problem367
- Charging Problem354
- Battery Problem335
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions8,987
- Insufficient Information290
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available25
- Low Blood Pressure/ Hypotension14
- Unspecified Vascular Problem14
- Hemorrhage/Blood Loss/Bleeding12
- Cardiac Arrest10
- Foreign Body In Patient7
- Aortic Valve Stenosis5
- Chest Pain4
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- Battery Charging Station; Model: 0998-00-0802;Open, Classified
Z-1587-2026 · Started Feb 6, 2026 · Posted by FDA Mar 19, 2026
Reason given: The Battery Charging Station is an optional dual-bay charger used to charge the Cardiosave IABP Lithium- Ion batteries when they are not being used to operate the IABP. Getinge has identified that a protruding screw in the left battery bay limits full insertion of certain batteries and prevents proper charging. The...
Cause as FDA categorized it: Under Investigation by firm
- CS100 IABP. Software Version CS100 IABP Q.01.Open, Classified
Z-1486-2026 · Started Jan 23, 2026 · Posted by FDA Mar 3, 2026
Reason given: The firm has identified that the battery runtime and cycle specifications contained in the devices Instructions for Use (IFU) need to be updated.
Cause as FDA categorized it: Under Investigation by firm
- CS300 IABP. Software Version CS300 IABP C.01.Open, Classified
Z-1487-2026 · Started Jan 23, 2026 · Posted by FDA Mar 3, 2026
Reason given: The firm has identified that the battery runtime and cycle specifications contained in the devices Instructions for Use (IFU) need to be updated.
Cause as FDA categorized it: Under Investigation by firm
- Cardiosave Hybrid. Intra-Aortic Balloon Pump system.Open, Classified
Z-0916-2026 · Started Nov 4, 2025 · Posted by FDA Dec 11, 2025
Reason given: The IFU addendum revises the Preventative Maintenance schedule to align with the update introduced in the Service Manual as of June 2023.
Cause as FDA categorized it: Component design/selection
- Cardiosave Rescue. Intra-Aortic Balloon Pump system.Open, Classified
Z-0917-2026 · Started Nov 4, 2025 · Posted by FDA Dec 11, 2025
Reason given: The IFU addendum revises the Preventative Maintenance schedule to align with the update introduced in the Service Manual as of June 2023.
Cause as FDA categorized it: Component design/selection
- Cardiosave HybridOpen, Classified
Z-0931-2026 · Started Oct 23, 2025 · Posted by FDA Dec 16, 2025
Reason given: The IFU addendum updates the Vibration and Shock Table to reference the correct standards.
Cause as FDA categorized it: Process change control
- Cardiosave RescueOpen, Classified
Z-0932-2026 · Started Oct 23, 2025 · Posted by FDA Dec 16, 2025
Reason given: The IFU addendum updates the Vibration and Shock Table to reference the correct standards.
Cause as FDA categorized it: Process change control
Z-2298-2025 · Started Jul 19, 2025 · Posted by FDA Aug 13, 2025
Reason given: Device contains indications for use and device compatibility claims that have not be reviewed and approved for safety and effectiveness by the FDA. Instructions for use are not consistent with product training.
Cause as FDA categorized it: No Marketing Application
Showing the 8 newest of 194 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.