Device type · FED
Endoscopic Access Overtube, Gastroenterology-Urology
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
FED
Gastroenterology & Urology
Device class
Class II
FDA decisions since 2015
51
510(k), De Novo and PMA
Adverse event reports
108
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Endoscopic Access Overtube, Gastroenterology-Urology
- Product code
- FED
- Device class
- Class II
- Review panel
- Gastroenterology & Urology
- Regulation
- 21 CFR 876.1500
- Specialty
- GI, Urology & Nephrology, Urology
- FDA record
- Classification database entry for FED
Latest FDA decisions
The 8 newest of 51 since 2015.
Yangzhou Fartley Medical Instrument Technology Co., Ltd.
K260512 · Decided Sep 21, 2026 · 216 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
K262262 · Decided Sep 18, 2026 · 78 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
Zhejiang Chuangxiang Medical Technology Co., Ltd.
K260410 · Decided Sep 11, 2026 · 214 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
K261915 · Decided Aug 4, 2026 · 56 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
- CVAC Aspiration System510(k)
K260965 · Decided Apr 13, 2026 · 21 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
- ClearEVAC Ureteral Aspirating Access Sheath (PUS-100-1040,PUS-100-1050, PUS-100-1240,PUS-100-1250)510(k)
Zhuhai Pusen Medical Technology Co., Ltd.
K260521 · Decided Apr 6, 2026 · 48 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
K252572 · Decided Oct 7, 2025 · 54 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
Anhui Happiness Workshop Medical Instruments Co., Ltd.
K250128 · Decided Sep 19, 2025 · 245 days after receipt
Device type: Endoscopic Access Overtube, Gastroenterology-Urology (FED) · GI, Urology & Nephrology
Reports received
108
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
67
62% of reports
Injury reports
39
36% of reports
Death reports
2
1.9% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 2 | 2 | 0 | 0 |
| Jan 24 | 3 | 0 | 0 | 0 |
| Feb 24 | 1 | 0 | 0 | 0 |
| Mar 24 | 2 | 1 | 0 | 0 |
| Apr 24 | 5 | 2 | 0 | 0 |
| May 24 | 4 | 2 | 2 | 0 |
| Jun 24 | 4 | 2 | 2 | 0 |
| Jul 24 | 7 | 0 | 0 | 0 |
| Aug 24 | 3 | 0 | 0 | 0 |
| Sep 24 | 12 | 0 | 0 | 0 |
| Oct 24 | 1 | 1 | 0 | 0 |
| Nov 24 | 3 | 0 | 1 | 0 |
| Dec 24 | 5 | 0 | 1 | 0 |
| Jan 25 | 1 | 0 | 0 | 0 |
| Feb 25 | 4 | 3 | 2 | 0 |
| Mar 25 | 8 | 1 | 0 | 0 |
| Apr 25 | 17 | 4 | 0 | 0 |
| May 25 | 2 | 7 | 0 | 0 |
| Jun 25 | 4 | 2 | 1 | 0 |
| Jul 25 | 8 | 0 | 0 | 0 |
| Aug 25 | 5 | 3 | 0 | 0 |
| Sep 25 | 5 | 1 | 0 | 0 |
| Oct 25 | 7 | 11 | 0 | 0 |
| Nov 25 | 6 | 0 | 0 | 0 |
| Dec 25 | 10 | 5 | 0 | 0 |
| Jan 26 | 7 | 2 | 0 | 0 |
| Feb 26 | 5 | 6 | 0 | 0 |
| Mar 26 | 5 | 0 | 0 | 0 |
| Apr 26 | 8 | 1 | 0 | 0 |
| May 26 | 5 | 3 | 2 | 0 |
| Jun 26 | 3 | 4 | 0 | 0 |
| Jul 26 | 3 | 2 | 0 | 0 |
| Aug 26 | 3 | 7 | 0 | 0 |
| Sep 26 | 9 | 5 | 0 | 0 |
| Oct 26 | 3 | 4 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Adverse Event Without Identified Device or Use Problem28
- Material Split, Cut or Torn25
- Material Deformation21
- Peeled/Delaminated13
- Detachment of Device or Device Component9
- Break6
- Material Integrity Problem5
- Material Separation5
- Insufficient Device Problem Information3
- Material Fragmentation3
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions69
- Perforation15
- Laceration(s)7
- Foreign Body In Patient6
- Hemorrhage/Blood Loss/Bleeding3
- Sepsis2
- Unspecified Kidney or Urinary Problem2
- Urethral Stenosis/Stricture2
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Hematoma1
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-1396-2025 · Started Feb 19, 2025 · Posted by FDA Mar 21, 2025
Reason given: Aspiration system, for endoscopic examination/treatment of urinary tract and kidney interior, to have labeling update adding additional instructions, for patients with high viscosity fluid in the kidney, not to continue providing fluid inflow in the presence of unresolved slow or absent fluid outflow because this can...
Cause as FDA categorized it: Device Design
- Sheath, 20 Fr., 130 mm (REF: WA2PS20S), gastroenterology-urology endoscopic access overtube.Open, Classified
Z-0713-2025 · Started Nov 27, 2024 · Posted by FDA Jan 10, 2025
Reason given: If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
Cause as FDA categorized it: Labeling False and Misleading
- Sheath, 20 Fr., 160 mm (REF: WA2PS20L), gastroenterology-urology endoscopic access overtube.Open, Classified
Z-0714-2025 · Started Nov 27, 2024 · Posted by FDA Jan 10, 2025
Reason given: If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
Cause as FDA categorized it: Labeling False and Misleading
- Sheath, 18 Fr., 130 mm (REF: WA2PS18S), gastroenterology-urology endoscopic access overtube.Open, Classified
Z-0715-2025 · Started Nov 27, 2024 · Posted by FDA Jan 10, 2025
Reason given: If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
Cause as FDA categorized it: Labeling False and Misleading
- Sheath, 18 Fr., 160 mm (REF: WA2PS18L), gastroenterology-urology endoscopic access overtube.Open, Classified
Z-0716-2025 · Started Nov 27, 2024 · Posted by FDA Jan 10, 2025
Reason given: If the inflow speed is too quick, it could result in reduced outflow through the shaft due to blood, tissue fragments and kidney stone fragments, and quickly build up of intrarenal pressure.
Cause as FDA categorized it: Labeling False and Misleading
Olympus Corporation of the Americas
Z-2423-2021 · Started Aug 3, 2021
Reason given: Packaging seal defect may allow a breach of the package sterile barrier and result in patient infection.
Cause as FDA categorized it: Equipment maintenance
Z-1718-2020 · Started Mar 11, 2020
Reason given: Updated Instructions For Use- to contraindications and potential complications/adverse events of the colonoscopy procedure (without using Endocuff Vision Device)
Cause as FDA categorized it: Other
Z-0440-2014 · Started Nov 5, 2013 · Posted by FDA Dec 4, 2013
Reason given: The 13F/15F Navigator HD Ureteral Access SheathSet are being recalled after receipt of 5 reports where the tip of the dilator has separated fro the body of the dilator.
Cause as FDA categorized it: Component design/selection
Showing the 8 newest of 12 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.