Device type · FGE
Stents, Drains And Dilators For The Biliary Ducts
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
FGE
Gastroenterology & Urology
Device class
Class II
FDA decisions since 2015
68
510(k), De Novo and PMA
Adverse event reports
1,997
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Stents, Drains And Dilators For The Biliary Ducts
- Product code
- FGE
- Device class
- Class II
- Review panel
- Gastroenterology & Urology
- Regulation
- 21 CFR 876.5010
- Specialty
- GI, Urology & Nephrology, Gastroenterology
- FDA record
- Classification database entry for FGE
Latest FDA decisions
The 8 newest of 68 since 2015.
- Drainage Catheter510(k)
K254179 · Decided Sep 18, 2026 · 269 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
K262913 · Decided Sep 17, 2026 · 29 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
Q3 Medical USA, LLC (C/O Q3 Medical Devices Ltd.)
K260835 · Decided Jul 27, 2026 · 136 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
Hangzhou AGS MedTech Co., Ltd.
K253393 · Decided Jun 24, 2026 · 267 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
Mirco-Tech (Nanjing) Co., Ltd.
K253832 · Decided Apr 24, 2026 · 144 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
K251658 · Decided Apr 16, 2026 · 321 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
K253987 · Decided Mar 13, 2026 · 91 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
Zhejiang Chuangxiang Medical Technology Co., Ltd.
K253132 · Decided Mar 6, 2026 · 162 days after receipt
Device type: Stents, Drains And Dilators For The Biliary Ducts (FGE) · GI, Urology & Nephrology
Reports received
1,997
Received Nov 1, 2025 to Nov 19, 2026. Includes 9 of another or unstated type.
Malfunction reports
1,657
83% of reports
Injury reports
321
16% of reports
Death reports
10
0.5% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 99 | 31 | 0 | 0 |
| Jan 24 | 101 | 16 | 1 | 0 |
| Feb 24 | 84 | 32 | 0 | 0 |
| Mar 24 | 106 | 37 | 0 | 0 |
| Apr 24 | 126 | 37 | 0 | 0 |
| May 24 | 132 | 31 | 1 | 0 |
| Jun 24 | 128 | 39 | 0 | 0 |
| Jul 24 | 177 | 23 | 0 | 0 |
| Aug 24 | 130 | 32 | 1 | 0 |
| Sep 24 | 125 | 32 | 1 | 0 |
| Oct 24 | 131 | 28 | 2 | 0 |
| Nov 24 | 121 | 58 | 2 | 0 |
| Dec 24 | 139 | 74 | 1 | 0 |
| Jan 25 | 120 | 17 | 1 | 0 |
| Feb 25 | 126 | 20 | 0 | 0 |
| Mar 25 | 148 | 31 | 1 | 0 |
| Apr 25 | 140 | 20 | 0 | 0 |
| May 25 | 127 | 32 | 1 | 0 |
| Jun 25 | 128 | 27 | 2 | 0 |
| Jul 25 | 128 | 25 | 0 | 0 |
| Aug 25 | 146 | 36 | 0 | 0 |
| Sep 25 | 132 | 29 | 1 | 0 |
| Oct 25 | 142 | 26 | 0 | 0 |
| Nov 25 | 125 | 24 | 0 | 0 |
| Dec 25 | 168 | 20 | 1 | 1 |
| Jan 26 | 115 | 44 | 0 | 0 |
| Feb 26 | 103 | 19 | 1 | 0 |
| Mar 26 | 156 | 26 | 0 | 0 |
| Apr 26 | 110 | 30 | 1 | 0 |
| May 26 | 114 | 18 | 3 | 1 |
| Jun 26 | 152 | 19 | 0 | 0 |
| Jul 26 | 184 | 30 | 0 | 1 |
| Aug 26 | 142 | 33 | 0 | 2 |
| Sep 26 | 158 | 32 | 3 | 4 |
| Oct 26 | 130 | 26 | 1 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
- Boston Scientific1,321
- Cook Ireland295
- Cook130
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Material Rupture392
- Adverse Event Without Identified Device or Use Problem294
- Break219
- Burst Container or Vessel132
- Inflation Problem126
- Activation Failure103
- Leak/Splash99
- Material Puncture/Hole93
- Detachment of Device or Device Component92
- Difficult to Remove88
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions1,793
- Insufficient Information39
- Restenosis35
- Foreign Body In Patient28
- Obstruction/Occlusion20
- Hemorrhage/Blood Loss/Bleeding19
- Pancreatitis19
- Perforation17
- Pain16
- Cholangitis15
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
Z-0143-2027 · Started Sep 10, 2026 · Posted by FDA Oct 9, 2026
Reason given: Device was incorrectly manufactured with a guidewire exit port (referred to in the IFU as the RX port), which is not a design feature associated with this device configuration.
Cause as FDA categorized it: Under Investigation by firm
Z-0158-2027 · Started Sep 3, 2026 · Posted by FDA Oct 14, 2026
Reason given: The potential for the devices to be mislabeled with the incorrect length.
Cause as FDA categorized it: Under Investigation by firm
- Olympus EZDilate Endoscopic Balloon Dilator Wired-guided 11, 12, 13mm. Model Number: BD-420X-1355.Open, Classified
Olympus Corporation of the Americas
Z-3216-2026 · Started Aug 19, 2026 · Posted by FDA Sep 18, 2026
Reason given: Potential for the inflation chart label affixed to the shaft of the device to be incorrect and indicate a balloon diameter of 18, 19, or 20 mm,
Cause as FDA categorized it: Process control
Z-2914-2026 · Started May 22, 2026 · Posted by FDA Aug 7, 2026
Reason given: 10 mm diameter x 7 cm with transmural drainage holes (VSWVH1006) incorrectly labeled as 10 mm diameter x 10 cm length devices without transmural drainage holes (VSWVN1010).
Cause as FDA categorized it: Process control
Z-2915-2026 · Started May 22, 2026 · Posted by FDA Aug 7, 2026
Reason given: 10 mm diameter x 7 cm with transmural drainage holes (VSWVH1006) incorrectly labeled as 10 mm diameter x 10 cm length devices without transmural drainage holes (VSWVN1010).
Cause as FDA categorized it: Process control
- CRE Pro Wireguided 6-8mm 240cmOpen, Classified
Z-2626-2026 · Started May 21, 2026 · Posted by FDA Jul 1, 2026
Reason given: Potential sterile breach of the pouches in which devices are packaged.
Cause as FDA categorized it: Package design/selection
- CRE Pro Wireguided 8-10mm 240cmOpen, Classified
Z-2627-2026 · Started May 21, 2026 · Posted by FDA Jul 1, 2026
Reason given: Potential sterile breach of the pouches in which devices are packaged.
Cause as FDA categorized it: Package design/selection
- CRE Pro Wireguided 10-12mm 240cmOpen, Classified
Z-2628-2026 · Started May 21, 2026 · Posted by FDA Jul 1, 2026
Reason given: Potential sterile breach of the pouches in which devices are packaged.
Cause as FDA categorized it: Package design/selection
Showing the 8 newest of 453 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.