Device type · NBC
Test, Natriuretic Peptide
Last checked: Nov 19, 2026Source: openFDAMethods & limitations
Product code
NBC
Clinical Chemistry
Device class
Class II
FDA decisions since 2015
12
510(k), De Novo and PMA
Adverse event reports
18
Received Nov 1, 2025 to Nov 19, 2026
How FDA classifies it
- Device type
- Test, Natriuretic Peptide
- Product code
- NBC
- Device class
- Class II
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1117
- Specialty
- Laboratory Medicine & Pathology
- FDA record
- Classification database entry for NBC
Latest FDA decisions
The 8 newest of 12 since 2015.
- Access BNP II510(k)
K262597 · Decided Oct 20, 2026 · 85 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
- Access NT-proBNP510(k)
K262109 · Decided Sep 21, 2026 · 90 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
- Access BNP II510(k)
K252169 · Decided Mar 24, 2026 · 257 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
K253539 · Decided Feb 18, 2026 · 97 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
K241176 · Decided Jan 16, 2025 · 262 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
- Access NT-proBNP510(k)
K232164 · Decided Apr 12, 2024 · 266 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
Siemens Healthcare Diagnostics, Inc.
K220265 · Decided Sep 24, 2023 · 601 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
K223637 · Decided Jul 21, 2023 · 228 days after receipt
Device type: Test, Natriuretic Peptide (NBC) · Laboratory Medicine & Pathology
Reports received
18
Received Nov 1, 2025 to Nov 19, 2026
Malfunction reports
17
94% of reports
Injury reports
1
5.6% of reports
Death reports
0
0.0% of reports
Adverse event reports received per month
By the date FDA received each report, stacked by event type. The newest month is incomplete.
- Malfunction
- Injury
- Death
- Other
View as table
| Month | Malfunction | Injury | Death | Other |
|---|---|---|---|---|
| Dec 23 | 2 | 0 | 0 | 0 |
| Jan 24 | 1 | 0 | 0 | 0 |
| Feb 24 | 1 | 0 | 0 | 0 |
| Mar 24 | 1 | 0 | 0 | 0 |
| Apr 24 | 0 | 0 | 0 | 0 |
| May 24 | 2 | 0 | 0 | 0 |
| Jun 24 | 2 | 0 | 0 | 0 |
| Jul 24 | 1 | 0 | 0 | 0 |
| Aug 24 | 1 | 0 | 0 | 0 |
| Sep 24 | 2 | 0 | 0 | 0 |
| Oct 24 | 2 | 0 | 0 | 0 |
| Nov 24 | 1 | 0 | 0 | 0 |
| Dec 24 | 0 | 0 | 0 | 0 |
| Jan 25 | 1 | 0 | 0 | 0 |
| Feb 25 | 4 | 1 | 0 | 0 |
| Mar 25 | 4 | 2 | 0 | 0 |
| Apr 25 | 0 | 0 | 0 | 0 |
| May 25 | 0 | 0 | 0 | 0 |
| Jun 25 | 0 | 0 | 0 | 0 |
| Jul 25 | 1 | 0 | 0 | 0 |
| Aug 25 | 2 | 0 | 0 | 0 |
| Sep 25 | 1 | 0 | 0 | 0 |
| Oct 25 | 0 | 0 | 0 | 0 |
| Nov 25 | 0 | 0 | 0 | 0 |
| Dec 25 | 1 | 0 | 0 | 0 |
| Jan 26 | 1 | 0 | 0 | 0 |
| Feb 26 | 3 | 0 | 0 | 0 |
| Mar 26 | 2 | 1 | 0 | 0 |
| Apr 26 | 4 | 0 | 0 | 0 |
| May 26 | 0 | 0 | 0 | 0 |
| Jun 26 | 1 | 0 | 0 | 0 |
| Jul 26 | 0 | 0 | 0 | 0 |
| Aug 26 | 0 | 0 | 0 | 0 |
| Sep 26 | 0 | 0 | 0 | 0 |
| Oct 26 | 5 | 0 | 0 | 0 |
| Nov 26 | 0 | 0 | 0 | 0 |
Manufacturers named most often
Last 12 months. Bigger sellers get more reports. This is not a ranking of safety.
Device problems as coded
Last 12 months. FDA's terms. A report can carry several.
- Low Test Results12
- Non Reproducible Results7
- High Test Results5
- Incorrect, Inadequate or Imprecise Result or Readings2
Patient problems as coded
Last 12 months. FDA's terms. A report can carry several.
- No Clinical Signs, Symptoms or Conditions17
- Insufficient Information1
Recent recalls
From FDA's recall database. FDA lists each recalled product separately, so one recall can appear several times. A recall is often a correction or a labeling change, not a removal from the market.
- The Quidel Triage BNP CalibratorsTerminated
Z-0297-2021 · Started Oct 1, 2020
Reason given: Product compromised during shipment.
Cause as FDA categorized it: Process control
Z-0689-2019 · Started Nov 1, 2018
Reason given: The firm is extending their previous July 2018 recall to include additional product codes. Biased results may occur for these additional products at biotin concentrations which are lower than indicated in the current Instructions for Use.
Cause as FDA categorized it: Device Design
Polymedco, Inc.,/Polymedco Cancer Diagnostic Products, Llc
Z-3186-2018 · Started Apr 30, 2018
Reason given: A pinhole caused by the laser printer in the aluminum sheet over the ALP reagent wells caused leakage through the pinhole. If the cartridge with leakage is used, higher measurement value as low as +12% and no higher than +20% bias may be obtained.
Cause as FDA categorized it: Process control
- ADVIA Centaur BNP (B-type Natriuretic Peptide), Catalog Numbers: 02816138 (100 tests), 02816634 (500 tests)Open, Classified
Siemens Healthcare Diagnostics, Inc.
Z-2053-2018 · Started Dec 18, 2017
Reason given: In certain scenarios the ADVIA Centaur CP, XP and XPT immunoassay analyzers may exhibit reduced dilution recovery or become inoperable when used with Multi-Diluent 15 and certain lots of BNP and TSH3RUL Assays.
Cause as FDA categorized it: Device Design
Z-1765-2017 · Started Mar 7, 2017
Reason given: Increased frequency of calibration failures for VITROS Immunodiagnostic Products NT-proBNP Reagent Lots 1568, 1570, 1580 and 1590, due to background signals for these affected NT-proBNP lots that have been increasing with time since release testing, resulting in higher than expected VITROS Immunodiagnostic Products...
Cause as FDA categorized it: Nonconforming Material/Component
Biomerieux France Chemin De L'Or
Z-2779-2016 · Started Apr 15, 2016 · Posted by FDA Sep 10, 2016
Reason given: Due to a packaging error; The kit does not contain the correct number of C1 or C2 control vials.
Cause as FDA categorized it: Packaging
Siemens Healthcare Diagnostics Inc
Z-0610-2016 · Started Nov 11, 2015 · Posted by FDA Jan 7, 2016
Reason given: Stratus CS Cartridge Barcode labels may not scan on the Stratus CS systems
Cause as FDA categorized it: Labeling design
Siemens Healthcare Diagnostics, Inc
Z-0229-2015 · Started Oct 6, 2014 · Posted by FDA Nov 19, 2014
Reason given: Siemens Healthcare Diagnostics has confirmed that approximately 2000 ReadyPacks from the ADVIA Centaur Systems BNP reagent contains an ADVIA Centaur Systems FT4 human-readable side label.
Cause as FDA categorized it: Labeling mix-ups
Showing the 8 newest of 22 recall records in FDA's data.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.